Convenient control
Regardless of whether you need to control hoists from ground level or want to control machinery, wire-connected DSK control pendants are the ideal solution.
Why?
- High level of safety
- For direct or contactor control
- Ergonomic design and operation
- Can be configured to meet a wide range of specific needs
Product information
The benefits at a glance
-
High safety and reliability
- Mechanical interlocking of the switching elements
- Movements in opposite directions cannot be simultaneously actuated
Performance to meet application requirements
- Direct control of drives with motor outputs up to 5.5 kW by using various switching elements
- Indirect control using contactors in the auxiliary circuit for higher outputs
Convenient operation
- Fatigue-free operation thanks to the ergonomical housing design
- Sloping control pendant design permits operators to work in a natural, comfortable posture
Customisable
- Can be configured to customer specifications (e.g. cable length)
Technical data
DSK series control pendants offer the following outstanding technical details:
- Permissible ambient temperatures from -25 °C to +70 °C
Control
- CBDN switching element (emergency stop) with positive opening of the NC contacts
- Direct control of drives up to 5.5 kW
- Simultaneous 2-pole switching for direct control
- Switching elements for direct or contactor control
Housing
- High-quality thermoplastic housing that is highly resistant to impacts
- Non-flammable, climate and corrision-proof
- Highly resistant to fuels, salt water, grease, oils and alkaline solutions
Safety
- Strain relief by means of special hose with additional protective sleeve, as standard
- Protective insulation to DIN VDE 0100 Part 410
- Switching distances and forces to DIN 33401, holding force < 8 N
- IP 55 enclosure to DIN VDE 0470 as standard in “suspended” operating position
- IP65 on request
Main current switching elements | ||||||
---|---|---|---|---|---|---|
Type | CBD 1 | CBD 2 | CBDN | |||
Design | Single-stage switching element 2 NO |
Double-stage switching element 2 NO in the 1st stage 2 changeover contacts in the 2nd stage |
Single-stage crane switch (emergency stop), 3 NC |
|||
Rated operating voltage [V] | 230 | 400 | 500 | 230 | 400 | 500 |
Rated operating current [A] | 20 | 12 | 9 | Ith 2 | 25 | |
Utilisation category to DIN VDE 0660 / EN 60947 Main current |
AC 3, AC 4 | AC 3, AC 4 | for breaking capacity up to 5.5 kW | |||
Nominal insulation voltage | Ui 500 V~ to DIN VDE 0110, CSA 300 VAC |
Control current switching element | ||||||
---|---|---|---|---|---|---|
Type | CBS 1 | CBS 2 | ||||
Design | Single-stage switching element 2 NO |
Double-stage switching element 2 NO in the 1st stage 1 sequence-controlled NO in the 2nd stage |
||||
Rated operating voltage [V] | 230 | 400 | 500 | 230 | 400 | 500 |
Rated operating current [A] | 10 | 6 | 4.5 | 10 | 6 | 4.5 |
Utilisation category to DIN VDE 0660 / EN 60947 Main current |
AC 15 | AC 15 | ||||
Nominal insulation voltage | Ui 500 V~ to DIN VDE 0110, CSA 150 V AC |